Exchange Queue monitoring must be configured with threshold and action.


Overview

Finding ID Version Rule ID IA Controls Severity
V-228363 EX16-MB-000100 SV-228363r508018_rule Medium
Description
Monitors are automated "process watchers" that respond to performance changes and can be useful in detecting outages and alerting administrators where attention is needed. Exchange has built-in monitors that enable the administrator to generate alerts if thresholds are reached, better enabling them to react in a timely fashion. This field offers choices of alerts when a "warning" or "critical" threshold is reached on the SMTP queue. A good rule of thumb (default) is to issue warnings when SMTP queue growth exceeds 10 minutes and critical messages when it exceeds 20 minutes, which should only happen occasionally. Frequent alerts against this counter may indicate a network or other issue (such as inbound ExchangeMER traffic) that directly impacts email delivery. Notification choices include email alert to an email-enabled account (for example, an email Administrator) or invoke a script to take other action (for example, to add an Event to the Microsoft Application Event Log, where external monitors might detect it).
STIG Date
Microsoft Exchange 2016 Mailbox Server Security Technical Implementation Guide 2020-10-01

Details

Check Text ( C-30596r496885_chk )
Note: If a third-party application is performing monitoring functions, the reviewer should verify the application is monitoring correctly and mark the vulnerability not applicable (NA).

Open the Exchange Management Shell and enter the following command:

perfmon
Get-MonitoringItemHelp -Identity -Server

If no sets are defined or queues are not being monitored, this is a finding.
Fix Text (F-30581r496886_fix)
Open the Exchange Management Shell and enter the following command:

perfmon

In the left pane, navigate to and select Performance >> Data Collector Sets >> User Defined.

Right-click on, navigate to, and configure User Defined >> New >> Data Collector Sets and configure the system to use the data collection set for monitoring the queues.