UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

Exchange Circular Logging must be disabled.


Overview

Finding ID Version Rule ID IA Controls Severity
V-207273 EX13-MB-000035 SV-207273r615936_rule Low
Description
Logging provides a history of events performed and can also provide evidence of tampering or attack. Failure to create and preserve logs adds to the risk that suspicious events may go unnoticed and raises the potential that insufficient history will be available to investigate them. This setting controls how log files are written. If circular logging is enabled, there is one log file stored with a default size of 1024 KB. Once the size limit has been reached, additional log entries overwrite the oldest log entries. If circular logging is disabled, once a log file reaches the size limit, a new log file is created. Mailbox should not use circular logging. Logs should be written to a partition separate from the operating system, with log protection and backups being incorporated into the overall System Security plan.
STIG Date
Microsoft Exchange 2013 Mailbox Server Security Technical Implementation Guide 2021-12-16

Details

Check Text ( C-7531r393332_chk )
Open the Exchange Management Shell and enter the following command:

Get-MailboxDatabase | Select Name, Identity, CircularLoggingEnabled

If the value of CircularLoggingEnabled is not set to False, this is a finding.
Fix Text (F-7531r393333_fix)
Open the Exchange Management Shell and enter the following command:

Set-MailboxDatabase -Identity <'IdentityName'> -CircularLoggingEnabled $false

Note: The value must be in quotes.