UCF STIG Viewer Logo

Remoting Services HTTP channels must utilize authentication and encryption.


Overview

Finding ID Version Rule ID IA Controls Severity
V-225228 APPNET0060 SV-225228r615940_rule Medium
Description
Note: Microsoft recommends using the Windows Communication Framework (WCF) rather than using .Net remoting. New development projects should refrain from using .Net remoting capabilities whenever possible. .NET remoting provides the capability to build widely distributed applications. The application components may reside all on one computer or they may be spread out across the enclave. .NET client applications can make remoting calls to use objects in other processes on the same computer or on any other computer that is reachable over the network. .NET remoting can also be used to communicate with other application domains within the same process. Remoting is achieved via the exposure of endpoints that can be used to establish remote connectivity. Normally when application code attempts to access a protected resource, a stack walk is performed to ensure that all stack frames have permission to access the resource. However, with .Net 4.0, when a call is made on a remote object, this stack walk is not performed across the remoting boundary. The .Net remoting infrastructure requires FullTrust permission to execute on either the client or the server. Due to the fact that FullTrust permission is required, Remoting endpoints should be authenticated and encrypted in order to protect the system and the data. Microsoft provides 3 different "channels" that are used for remoting. They are HTTP, TCP and IPC. Any unauthorized use of a remoting application provides unauthorized access with FullTrust permissions to the system. This can potentially result in a loss of system integrity or confidentiality.
STIG Date
Microsoft DotNet Framework 4.0 Security Technical Implementation Guide 2022-09-13

Details

Check Text ( C-26927r467999_chk )
Review the machine.config file and the [application name].exe.config file.

For 32 bit systems, the "machine.config" file is contained in the following folder. %SYSTEMROOT%\Microsoft.NET\Framework\v4.0.30319\Config

For 64 bit systems, the "machine.config" file is contained in the following folder. %SYSTEMROOT%\Microsoft.NET\Framework64\v4.0.30319\Config.

Microsoft specifies locating the [application].config file in the same folder as the application executable (.exe) file. However, the developer does have the capability to specify a different location when the application is compiled. Therefore, if the file is not found in the application home folder, a search of the system is required. If the [application name].exe.config file is not found on the system, then only a check of the machine.config file is required.

Sample machine/application config file:
















Microsoft provides 3 "channels" that are used for remoting connectivity. They are the HTTP, TCP and IPC channels. The channel that is used is specified via the element in the config file.

HTTP channel example:


The HTTP Channel only supports encryption and message integrity when the remote object is hosted in Internet Information Services (IIS) using TLS.

The above example shows the well known TLS port of 443 is not being used.

If the HTTP remoting channel is not configured to protect the channel by using TLS encryption, this is a finding.

Fix Text (F-26915r468000_fix)
Ensure encryption and message integrity are used for HTTP remoting channels.

The HTTP Channel only supports encryption and message integrity when the remote object is hosted in Internet Information Services (IIS) using TLS.

HTTP channels are protected via TLS (HTTPS).




Change the channel ref parameter to utilize a TLS port and leverage TLS on the remote IIS server.