UCF STIG Viewer Logo

MarkLogic Server must be a version supported by the vendor.


Overview

Finding ID Version Rule ID IA Controls Severity
V-259796 ML09-00-012500 SV-259796r947223_rule High
Description
Unsupported commercial and database systems should not be used because fixes to newly identified bugs will not be implemented by the vendor. The lack of support can result in potential vulnerabilities. Systems at unsupported servicing levels or releases will not receive security updates for new vulnerabilities, which leaves them subject to exploitation. When maintenance updates and patches are no longer available, the database software is no longer considered supported and should be upgraded or decommissioned.
STIG Date
MarkLogic Server v9 Security Technical Implementation Guide 2024-01-24

Details

Check Text ( C-54617r947222_chk )
Review the system documentation and interview the database administrator.

Identify all database software components.

Review the current version and release information; execute the following from the query console:
xdmp:version();
--OR--
Perform the check from the MarkLogic Server Admin Interface with a user that holds administrative-level privileges.
Version is displayed in the upper left corner of the console.

Access the MarkLogic website to validate that the version is currently supported:
https://developer.marklogic.com/products/support-matrix/

If the DBMS or any of the software components are not supported by the vendor, this is a finding.
Fix Text (F-54571r947223_fix)
Remove or decommission all unsupported software products.