UCF STIG Viewer Logo

The Juniper SRX Services Gateway must record time stamps for log records using Coordinated Universal Time (UTC).


Overview

Finding ID Version Rule ID IA Controls Severity
V-223201 JUSX-DM-000065 SV-223201r513292_rule Medium
Description
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. UTC is normally used in DoD; however, Greenwich Mean Time (GMT) may be used if needed for mission requirements.
STIG Date
Juniper SRX SG NDM Security Technical Implementation Guide 2021-03-25

Details

Check Text ( C-24874r513290_chk )
Verify the time zone is set to UTC.

[edit]
show system time-zone

If the time zone is not set to UTC, this is a finding.
Fix Text (F-24862r513291_fix)
The following command sets the time zone to UTC.

[edit]
set system time-zone UTC