Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-217334 | JUNI-ND-001020 | SV-217334r991992_rule | Medium |
Description |
---|
The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run mode) and increasingly inaccurate time stamps on audit events and other functions. Multiple time sources provide redundancy by including a secondary source. Time synchronization is usually a hierarchy; clients synchronize time to a local source while that source synchronizes its time to a more accurate source. The network device must utilize an authoritative time server and/or be configured to use redundant authoritative time sources. This requirement is related to the comparison done in CCI-001891. DoD-approved solutions consist of a combination of a primary and secondary time source using a combination or multiple instances of the following: a time server designated for the appropriate DoD network (NIPRNet/SIPRNet); United States Naval Observatory (USNO) time servers; and/or the Global Positioning System (GPS). The secondary time source must be located in a different geographic region than the primary time source. |
STIG | Date |
---|---|
Juniper Router NDM Security Technical Implementation Guide | 2024-06-12 |
Check Text ( C-18561r296580_chk ) |
---|
Review the router configuration to verify that it is compliant with this requirement as shown in the configuration example below. system { … … … } ntp { server x.x.x.x prefer; server x.x.x.x; } If the router is not configured to synchronize its clock with redundant authoritative time sources, this is a finding. |
Fix Text (F-18559r296581_fix) |
---|
Configure the router to synchronize its clock with redundant authoritative time sources as shown in the example below. [edit system ntp] set server x.x.x.x set server x.x.x.x prefer |