UCF STIG Viewer Logo

The Juniper router must be configured to terminate all network connections associated with device management after 10 minutes of inactivity.


Overview

Finding ID Version Rule ID IA Controls Severity
V-217328 JUNI-ND-000710 SV-217328r539622_rule High
Description
Terminating an idle session within a short time period reduces the window of opportunity for unauthorized personnel to take control of a management session enabled on the console or console port that has been left unattended. In addition, quickly terminating an idle session will also free up resources committed by the managed network element. Terminating network connections associated with communications sessions includes, for example, de-allocating associated TCP/IP address/port pairs at the operating system level, or de-allocating networking assignments at the application level if multiple application sessions are using a single, operating system-level network connection. This does not mean that the device terminates all sessions or network access; it only ends the inactive session and releases the resources associated with that session.
STIG Date
Juniper Router NDM Security Technical Implementation Guide 2022-09-12

Details

Check Text ( C-18555r296562_chk )
Review the router configuration to verify that all login classes have the idle-timeout value to 10 minutes or less as shown in the following example:

system {



}
login {
class ADMIN {
idle-timeout 10;
permissions admin-control;
}
}

If the router is not configured to terminate all network connections associated with a device management after 10 minutes of inactivity, this is a finding.
Fix Text (F-18553r296563_fix)
Set the idle timeout value to 10 minutes or less on all configured login classes as shown in the example below.

[edit system login]
set class ADMIN idle-timeout 10