UCF STIG Viewer Logo

MobileIron Sentry must generate an immediate real-time alert of all audit failure events requiring real-time alerts.


Overview

Finding ID Version Rule ID IA Controls Severity
V-250998 MOIS-ND-000690 SV-250998r802216_rule Low
Description
It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected.
STIG Date
Ivanti MobileIron Sentry 9.x NDM Security Technical Implementation Guide 2021-09-15

Details

Check Text ( C-54433r802214_chk )
Verify the MobileIron Sentry is configured to send alerts for failure events in MobileIron Sentry System Manager web GUI.

1. Log in to MobileIron Sentry.
2. Go to Monitoring >> Alert Configuration.
3. Verify Alert monitoring is configured.

If Alert Configuration settings are not configured, this is a finding.

Refer to the "Alert Configuration" section of the "MobileIron Sentry 9.8.0 Guide for MobileIron Core" for more information.
Fix Text (F-54387r802215_fix)
Configure the MobileIron Sentry to send alerts for failure events in MobileIron Sentry System Manager web GUI.

1. Log in to MobileIron Sentry.
2. Go to Monitoring >> Alert Configuration.
3. Check "Send Notification".
4. Apply Email List.
5. Enter Alerts Per Hour.
6. Enter Batch Time Interval (min).
7. Select "Default Alert Action".
8. Apply.
9. Add Alert Notification Management.
10. Add Alert ID.
11. Add "Action" from dropdown.
12. Click "Apply" and "Save" in the top right corner.

Refer to the "Alert Configuration" section of the "MobileIron Sentry 9.8.0 Guide for MobileIron Core" for more information.