Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-258604 | IVCS-NM-000120 | SV-258604r961443_rule | Medium |
Description |
---|
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. Time stamps generated by the application include date and time. Time is commonly expressed in Coordinated Universal Time (UTC), a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC. |
STIG | Date |
---|---|
Ivanti Connect Secure NDM Security Technical Implementation Guide | 2024-06-10 |
Check Text ( C-62344r930498_chk ) |
---|
In the ICS Web UI, navigate to System >> Status >> Dashboard. 1. Click the "Overview" tab. 2. Under "Appliance Details" and "System Date and Time", select "Edit". 3. Verify the "Time Zone" is set to "(GMT) Coordinated Universal Time". If the ICS must be configured to record time stamps for audit records that can be mapped to GMT, this is a finding. |
Fix Text (F-62253r930499_fix) |
---|
In the ICS Web UI, navigate to System >> Status >> Dashboard. 1. Click the "Overview" tab. 2. Under "Appliance Details" and "System Date and Time", select "Edit". 3. Select "(GMT) Coordinated Universal Time". 4. Click "Save Changes". |