UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The web-site must limit the number of bytes accepted in a request.


Overview

Finding ID Version Rule ID IA Controls Severity
V-26041 WA000-WI6210 SV-32692r3_rule Medium
Description
By setting limits on web requests, it ensures availability of web services and mitigates the risk of buffer overflow type attacks. The maxAllowedContentLength Request Filter limits the number of bytes the server will accept in a request.
STIG Date
IIS 7.0 WEB SITE STIG 2017-01-04

Details

Check Text ( C-32889r2_chk )
For each site reviewed:
1. Open the IIS Manager.
2. Click on the site name.
3. Double-click the Request Filtering icon.
4. Click Edit Feature Settings in the Actions Pane.

If the maxAllowedContentLength value is not set to 30000000, this is a finding.

NOTE: If the site has operational reasons to set maxAllowedContentLength to an alternate value, and has supporting documentation signed by the ISSO, this is not a finding.
Fix Text (F-29035r1_fix)
1. Open the IIS Manager.
2. Click the site name under review.
3. Double-click the Request Filtering icon.
4. Click Edit Feature Settings in the Actions Pane.
5. Set the maxAllowedContentLength value to 30000000.