UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The production web-site must configure the Maximum Query String limit.


Overview

Finding ID Version Rule ID IA Controls Severity
V-26043 WA000-WI6230 SV-32694r3_rule ECSC-1 Medium
Description
By setting limits on web requests, it helps to ensure availability of web services and may also help mitigate the risk of buffer overflow type attacks. The Maximum Query String Request Filter describes the upper limit on allowable query string lengths. Upon exceeding the configured value, IIS will generate a Status Code 404.15.
STIG Date
IIS 7.0 WEB SITE STIG 2015-06-01

Details

Check Text ( C-32891r2_chk )
For each site reviewed:
1. Open the IIS Manager.
2. Click on the site name.
3. Double-click the Request Filtering icon.
4. Click Edit Feature Settings in the Actions Pane.

If the Maximum Query String value is not set to 2048, this is a finding.

NOTE: If the site has operational reasons to set Maximum Query String to an alternate value, and has supporting documentation signed by the ISSO, this is not a finding.
Fix Text (F-29037r1_fix)
1. Open the IIS Manager.
2. Click the site name under review.
3. Double-click the Request Filtering icon.
4. Click Edit Feature Settings in the Actions Pane.
5. Set the Maximum Query String value to 2048.