The Idle Timeout monitor must be enabled.


Overview

Finding ID Version Rule ID IA Controls Severity
V-13708 WA000-WI6028 IIS7 SV-32572r1_rule ECSC-1 Medium
Description
The idle time-out attribute controls the amount of time a worker process will remain idle before it shuts down. A worker process is idle if it is not processing requests and no new requests are received. The purpose of this attribute is to conserve system resources; the default value for idle time-out is 20 minutes. By default, the World Wide Web (WWW) service establishes an overlapped recycle, in which the worker process to be shut down is kept running until after a new worker process is started.
STIG Date
IIS 7.0 WEB SITE STIG 2013-04-11

Details

Check Text ( C-32857r1_chk )
1. Open the IIS Manager.
2. Click the Application Pools.
3. Highlight an Application Pool to review and click Advanced Settings in the Actions Pane.
4. Scroll down to the Process Model section and ensure the value for Idle Time out is set to 20. If not, this is a finding.

NOTE: If the site has operational reasons to set Idle Time out to an alternate value, and has supporting documentation signed by the IAO, this is not a finding.
Fix Text (F-28992r1_fix)
1. Open the IIS Manager.
2. Click the Application Pools.
3. Highlight an Application Pool to review and click Advanced Settings in the Actions Pane.
4. Scroll down to the Process Model section and set the value for Idle Time-out to 20.