The IDPS must capture and log alerts that contain detailed information for events identified by type, location, and subject.


Overview

Finding ID Version Rule ID IA Controls Severity
SRG-NET-000080-IDPS-000077 SRG-NET-000080-IDPS-000077 SRG-NET-000080-IDPS-000077_rule Low
Description
Audit record content that may be necessary to satisfy the requirement of this control, includes, timestamps, source and destination addresses, user/process identifiers, event descriptions, success/fail indications, filenames involved, and access control or flow control rules invoked. This capability is critical for accurate forensic analysis.
STIG Date
IDPS Security Requirements Guide (SRG) 2012-03-08

Details

Check Text ( C-43205_chk )
Verify log view setting can be reorganized to view the log entries by type, location or subject.
Verify the sensor logs categorize each event logged by a minimum event type, location, and a description of the event.

If sensor logs entries do not include a minimum of event type, location, and a description of the event for each event captured, this is a finding.
Fix Text (F-43205_fix)
Configure the sensors and central management server to categorize each alert. Alerts will include event type, location, and a description of the event.