UCF STIG Viewer Logo

IBM z/OS PARMLIB CLOCKxx must have the Accuracy PARM coded properly.


Overview

Finding ID Version Rule ID IA Controls Severity
V-224025 TSS0-OS-000290 SV-224025r561402_rule Medium
Description
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network. Organizations should consider setting time periods for different types of systems (e.g., financial, legal, or mission-critical systems). Organizations should also consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints). This requirement is related to the comparison done every 24 hours in SRG-OS-000355 because a comparison must be done in order to determine the time difference.
STIG Date
IBM z/OS TSS Security Technical Implementation Guide 2022-01-05

Details

Check Text ( C-25698r516474_chk )
Refer to the CLOCKxx member of PARMLIB.

If the ACCURACY parm is not coded, this is a finding.

If the ACCURACY parm is coded to "1000", this is not a finding.
Fix Text (F-25686r516475_fix)
Define the CLOCKxx statement to include the ACCURACY parm set to "1000".