The CA-TSS HPBPW Control Option must be set to three days maximum.


Overview

Finding ID Version Rule ID IA Controls Severity
V-223933 TSS0-ES-000600 SV-223933r561402_rule Medium
Description
Configuring the operating system to implement organization-wide security implementation guides and security checklists ensures compliance with federal standards and establishes a common security baseline across DoD that reflects the most restrictive security posture consistent with operational requirements.
STIG Date
IBM z/OS TSS Security Technical Implementation Guide 2021-07-06

Details

Check Text ( C-25606r516198_chk )
From the ISPF Command enter:
TSS MODIFY STATUS

If the HPBPW Control Option value is set to (3) days maximum, this is not a finding.

If the HPBPW Control Option value is set to greater than (3) days, this is a finding.
Fix Text (F-25594r516199_fix)
Evaluate the impact associated with implementation of the control option. Develop a plan of action to implement the HPBPW control option setting to a maximum of 3 days.