IBM Integrated Crypto Service Facility (ICSF) Started task(s) must be properly defined to the STARTED resource class for RACF.


Overview

Finding ID Version Rule ID IA Controls Severity
V-255938 RACF-IC-000050 SV-255938r958482_rule Medium
Description
Access to product resources should be restricted to only those individuals responsible for the application connectivity and who have a requirement to access these resources. Improper control of product resources could potentially compromise the operating system, ACP, and customer data.
STIG Date
IBM z/OS RACF Security Technical Implementation Guide 2024-06-24

Details

Check Text ( C-59615r881304_chk )
Execute the RACF DSMON report for RACSPT

if the IBM Integrated Crypto Service Facility (ICSF) started task(s) is (are) not defined to the STARTED resource class profile and/or ICHRIN03 table entry this is a finding
Fix Text (F-59558r881305_fix)
Ensure that a product's started task(s) is (are) properly identified and/or defined to the System ACP.

A unique userid must be assigned for the IBM Integrated Crypto Service Facility (ICSF) started task(s) thru a corresponding STARTED class entry.

The following sample set of commands is shown here as a guideline:

rdef started CSFSTART.** uacc(none) owner(admin) audit(all(read)) stdata(user(CSFSTART) group(stc))

setr racl(started) ref