IBM z/OS SNTP daemon (SNTPD) permission bits must be properly configured.


Overview

Finding ID Version Rule ID IA Controls Severity
V-223775 RACF-OS-000190 SV-223775r877038_rule Medium
Description
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time, a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network. Organizations should consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints).
STIG Date
IBM z/OS RACF Security Technical Implementation Guide 2023-06-13

Details

Check Text ( C-25448r515013_chk )
From the ISPF Command Shell enter:
cd /usr/sbin
ls -al

If the following File permission and user Audit Bits are true, this is not a finding.

/usr/sbin/sntpd 1740 faf

The following represents a hierarchy for permission bits from least restrictive to most restrictive:

7 rwx (least restrictive)
6 rw-
3 -wx
2 -w-
5 r-x
4 r--
1 --x
0 --- (most restrictive)

The possible audit bits settings are as follows:

f log for failed access attempts
a log for failed and successful access
- no auditing
Fix Text (F-25436r515014_fix)
With the assistance of a systems programmer with UID(0) and/or SUPERUSER access, configure the UNIX permission bits and user audit bits on the SNTPD to conform to the specifications below:

/usr/sbin/sntpd 1740 faf