UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

IBM z/OS system administrators must develop an automated process to collect and retain SMF data.


Overview

Finding ID Version Rule ID IA Controls Severity
V-223771 RACF-OS-000150 SV-223771r604139_rule Medium
Description
Information stored in one location is vulnerable to accidental or incidental deletion or alteration. Off-loading is a common process in information systems with limited audit storage capacity.
STIG Date
IBM z/OS RACF Security Technical Implementation Guide 2021-03-30

Details

Check Text ( C-25444r515001_chk )
Ask the system administrator if there is an automated process is in place to collect and retain all SMF data produced on the system.

If, based on the information provided, it can be determined that an automated process is in place to collect and retain all SMF data produced on the system, this is not a finding.

If it cannot be determined this process exists and is being adhered to, this is a finding.
Fix Text (F-25432r515002_fix)
The ISSO will ensure that an automated process is in place to collect SMF data.

Review SMF data collection and retention processes. Develop processes are automatically started to dump SMF collection files immediately upon their becoming full.

To ensure that all SMF data is collected in a timely manner, and to reduce the risk of data loss, the site will ensure that automated mechanisms are in place to collect and retain all SMF data produced on the system. Dump the SMF files (MANx) in systems based on the following guidelines:

-Dump each SMF file as it fills up during the normal course of daily processing
-Dump all remaining SMF data at the end of each processing day or
-Establish a process using Audit logging