UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

CA-ACF2 must limit Write or greater access to SYS1.NUCLEUS to system programmers only.


Overview

Finding ID Version Rule ID IA Controls Severity
V-223445 ACF2-ES-000240 SV-223445r853510_rule High
Description
To mitigate the risk of unauthorized access to sensitive information by entities that have been issued certificates by DoD-approved PKIs, all DoD systems (e.g., web servers and web portals) must be properly configured to incorporate access control methods that do not rely solely on the possession of a certificate for access. Successful authentication must not automatically give an entity access to an asset or security boundary. Authorization procedures and controls must be implemented to ensure each authenticated entity also has a validated and current authorization. Authorization is the process of determining whether an entity, once authenticated, is permitted to access a specific asset. Information systems use access control policies and enforcement mechanisms to implement this requirement. Access control policies include: identity-based policies, role-based policies, and attribute-based policies. Access enforcement mechanisms include: access control lists, access control matrices, and cryptography. These policies and mechanisms must be employed by the application to control access between users (or processes acting on behalf of users) and objects (e.g., devices, files, records, processes, programs, and domains) in the information system. Satisfies: SRG-OS-000080-GPOS-00048, SRG-OS-000259-GPOS-00100, SRG-OS-000324-GPOS-00125
STIG Date
IBM z/OS ACF2 Security Technical Implementation Guide 2022-12-14

Details

Check Text ( C-25118r504467_chk )
If all of the following are untrue, this is not a finding.

If any of the following is true, this is a finding.

The ACP data set rules for SYS1.NUCLEUS do not restrict UPDATE and/or ALTER access to only z/OS systems programming personnel.

The ACP data set rules for SYS1.NUCLEUS do not specify that all (i.e., failures and successes) UPDATE and/or ALTER access will be logged.
Fix Text (F-25106r504468_fix)
Review access authorization to critical system files. Evaluate the impact of correcting the deficiency. Develop a plan of action and implement the changes required to protect SYS1.NUCLEUS.

Configure the update and allocate access to SYS1.NUCLEUS to be limited to system programmers only and all update and allocate access is logged.