UCF STIG Viewer Logo

On Classified Systems the Processor Resource/Systems Manager (PR/SM) must not allow access to system complex data.


Overview

Finding ID Version Rule ID IA Controls Severity
V-24382 HLP0050 SV-30057r2_rule ECCD-1 ECCD-2 Medium
Description
Allowing unrestricted access to all Logical Partition data could result in the possibility of unauthorized access and updating of data. This could also impact the integrity of the processing environment.
STIG Date
IBM Hardware Management Console (HMC) STIG 2017-09-28

Details

Check Text ( C-3644r1_chk )
Have the Systems Administrator or Systems Programmer use the Hardware Management Console; to verify that the classified Logical Partition system data cannot be viewed by other Logical Partitions.

Use the Security Definitions Panel to do this. The Global Performance Data Control option must be turned off.

NOTE: The default is that the Global Performance Data Control option is turned off.

If the PR/SM allows access to system complex data then, this is a FINDING.
Fix Text (F-2349r1_fix)
Have the Systems Administrator or Systems Programmer use the Hardware Management Console, to verify that the classified Logical Partition system data cannot be viewed by other Logical Partitions.

Use the Security Definitions Panel to do this. The Global Performance Data Control option must be turned off.