The DataPower Gateway must activate a system alert message, send an alarm, and/or automatically shut down when a component failure is detected.


Overview

Finding ID Version Rule ID IA Controls Severity
V-65111 WSDP-NM-000076 SV-79601r1_rule Medium
Description
Predictable failure prevention requires organizational planning to address device failure issues. If components key to maintaining the device's security fail to function, the device could continue operating in an insecure state. If appropriate actions are not taken when a network device failure occurs, a denial of service condition may occur which could result in mission failure since the network would be operating without a critical security monitoring and prevention function. Upon detecting a failure of network device security components, the network device must activate a system alert message, send an alarm, or shut down.
STIG Date
IBM DataPower Network Device Management Security Technical Implementation Guide 2017-10-05

Details

Check Text ( C-65739r1_chk )
From the DataPower command line, enter "failure-notification", then enter "show failure-notification". If it is "disabled", this is a finding. This capability is enabled by default.
Fix Text (F-71051r1_fix)
From the DataPower command line, enter "failure-notification" to configure DataPower to generate failure notifications.

With failure notification enabled, you can send an error report to a designated recipient or upload to a specific location after the appliance returns to service from an unscheduled outage.