UCF STIG Viewer Logo

The DataPower Gateway must protect audit tools from unauthorized deletion.


Overview

Finding ID Version Rule ID IA Controls Severity
V-65081 WSDP-NM-000041 SV-79571r1_rule Medium
Description
Protecting audit data also includes identifying and protecting the tools used to view and manipulate log data. Therefore, protecting audit tools is necessary to prevent unauthorized operations on audit data. Network devices providing tools to interface with audit data will leverage user permissions and roles identifying the user accessing the tools and the corresponding rights the user enjoys in order to make access decisions regarding the access to audit tools. Audit tools include, but are not limited to, vendor-provided and open source audit tools needed to successfully view and manipulate audit information system activity and records. Audit tools include custom queries and report generators.
STIG Date
IBM DataPower Network Device Management Security Technical Implementation Guide 2017-10-05

Details

Check Text ( C-65707r1_chk )
Logon page >> Enter non-admin user ID and password, select Default for domain >> Click "Login". If non-admin user can log on, this is a finding.
Fix Text (F-71021r1_fix)
Privileged account user log on to default domain >> Administration >> Access >> User Account >> Select non privileged user account >> Click “…” button next to User Group field >> Enter */default/*?Access=NONE into field >> Click "Add >> Click "Apply" >> Click "Apply" >> Click "Save Configuration".