UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The DataPower Gateway must not use 0.0.0.0 as the management IP address.


Overview

Finding ID Version Rule ID IA Controls Severity
V-65189 WSDP-NM-000143 SV-79679r1_rule Medium
Description
If 0.0.0.0 as the management IP address, the DataPower appliance will listen on all configured interfaces for management traffic. This can allow an attacker to gain privileged-level access from an untrusted network.
STIG Date
IBM DataPower Network Device Management Security Technical Implementation Guide 2016-01-21

Details

Check Text ( C-65817r1_chk )
Using an administrator account, log on to the default domain of the appliance.

Navigate to Network >> Management >> Web Management Service.

View the Local Address field; if the value is “0.0.0.0”, this is a finding.
Fix Text (F-71129r1_fix)
To configure the DataPower appliance for web management:

Using an administrator account, log on to the default domain of the appliance.

On the Configure Web Management Service screen, complete the required information.

Set the Administrative state to “enabled”.

For the Local Address, use the IP address from the management subnet assigned to the unit.