UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The DataPower Gateway must use automated mechanisms to alert security personnel to threats identified by authoritative sources (e.g., CTOs) and in accordance with CJCSM 6510.01B.


Overview

Finding ID Version Rule ID IA Controls Severity
V-65173 WSDP-NM-000131 SV-79663r1_rule Medium
Description
By immediately displaying an alarm message, potential security violations can be identified more quickly even when administrators are not logged into the network device. An example of a mechanism to facilitate this would be through the utilization of SNMP traps.
STIG Date
IBM DataPower Network Device Management Security Technical Implementation Guide 2016-01-21

Details

Check Text ( C-65801r1_chk )
Go to Administration >> Access >> SNMP Settings. Verify the IP address, port, and security settings. Go to the Trap and Notification Targets tab. Verify the remote server/receiver information. If these values have not been set, this is a finding.
Fix Text (F-71113r1_fix)
Go to Administration >> Access >> SNMP Settings. Configure the IP address, port, and security settings.

Go to the Trap and Notification Targets tab. Enter the remote server/receiver information.