UCF STIG Viewer Logo

The DataPower Gateway must provide an immediate real-time alert to, at a minimum, the SCA and ISSO, of all audit failure events where the detection and/or prevention function is unable to write events to either local storage or the centralized server.


Overview

Finding ID Version Rule ID IA Controls Severity
V-65261 WSDP-AG-000091 SV-79751r1_rule Medium
Description
Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected. Alerts provide organizations with urgent messages. Real-time alerts provide these messages immediately (i.e., the time from event detection to alert occurs in seconds or less). This does not apply to audit logs generated on behalf of the device itself (management).
STIG Date
IBM DataPower ALG Security Technical Implementation Guide 2016-01-21

Details

Check Text ( C-65889r1_chk )
Examine configuration of Log targets (type “Log Target” in navigation search box) to verify a target that delivers Critical messages.

If no log targets are configured, this is a finding.
Fix Text (F-71201r1_fix)
Log Target to send all Critical log messages to the desired destination.

Search Bar “Log Target” >> Add >> Name log target name >> Target Type “SOAP” >> URL dest url

Event Subscriptions tab >> Add >> Event Category “all” >> Minimum Event Priority “critical”