Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-215208 | AIX7-00-001053 | SV-215208r508663_rule | Medium |
Description |
---|
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network. Organizations should consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints). Satisfies: SRG-OS-000355-GPOS-00143, SRG-OS-000356-GPOS-00144 |
STIG | Date |
---|---|
IBM AIX 7.x Security Technical Implementation Guide | 2020-09-11 |
Check Text ( C-16406r294075_chk ) |
---|
Check if time synchronization application "ntpd" is running using the command: # lssrc -s xntpd Subsystem Group PID Status xntpd tcpip 4784536 active If "ntpd" is showing "inoperative", this is a finding. Check that "ntp" server is configured using command: # grep server /etc/ntp.conf server 10.110.20.10 If the command returns no output, this is a finding. Check the poll interval is less than 24 hours using command: # grep maxpoll /etc/ntp.conf maxpoll=16 If "maxpoll" is set to larger than "16" (2^16 seconds ~= 18hr), this is a finding. |
Fix Text (F-16404r294076_fix) |
---|
Edit /etc/ntp.conf Configure ntp server by adding the following line: server server_ipaddr Set maxpoll to Restart the ntp daemon. # stopsrc -s xntpd # startsrc -s xntpd |