The HYCU server must be configured to synchronize internal information system clocks using redundant authoritative time sources.


Overview

Finding ID Version Rule ID IA Controls Severity
V-246842 HYCU-AU-000019 SV-246842r768190_rule Medium
Description
The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run mode) and increasingly inaccurate time stamps on audit events and other functions.
STIG Date
HYCU for Nutanix Security Technical Implementation Guide 2021-08-03

Details

Check Text ( C-50274r768188_chk )
HYCU is a VM that synchronizes time with the Nutanix or VMware platform as part of maintenance task using the "chronyd" daemon.

To verify the service is up and running, execute the following command:
systemctl status chronyd

If service is not active (running), this is a finding.
Fix Text (F-50228r768189_fix)
Verify time synchronization by logging on to the HYCU console and executing the following command:
sudo systemctl start chronyd