UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The HYCU Web UI must generate an immediate real-time alert of all audit failure events requiring real-time alerts.


Overview

Finding ID Version Rule ID IA Controls Severity
V-246841 HYCU-AU-000018 SV-246841r768187_rule Medium
Description
It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected.
STIG Date
HYCU for Nutanix Security Technical Implementation Guide 2021-08-03

Details

Check Text ( C-50273r768185_chk )
Log on to the HYCU Web UI and review the Events menu and Email Notifications to verify that all appropriate/relevant audit failure events are included in the "Category" drop-down menu.

If these events are not shown (reference a recent event capturing a login to HYCU for validation), this is a finding.
Fix Text (F-50227r768186_fix)
Log on to the HYCU Web UI and go to the "Events" menu and open "Email Notifications".

Ensure that all the appropriate/relevant categories are selected and that the "Status" includes failures.

Add a "Subject" for the Email Notifications and email address for necessary auditors or HYCU administrators.