Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-255277 | HP3P-33-001400 | SV-255277r986303_rule | Medium |
Description |
---|
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network. Organizations should consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints). The HPE 3PAR OS maintains an internal synchronization of node clocks, and aligns that with an NTP client always running on the network owner node when configured as shown. |
STIG | Date |
---|---|
HPE 3PAR StoreServ 3.3.x Security Technical Implementation Guide | 2024-05-30 |
Check Text ( C-58950r870148_chk ) |
---|
Verify NTP is operational: cli% shownet If any of the NTP Server lines in the output show an incorrect NTP Server address, this is a finding. If only one NTP Server line is present, and it indicates "None" for the address, this is a finding. |
Fix Text (F-58894r870149_fix) |
---|
Enable NTP with: cli% setnet ntp -add This command can be used multiple times to specify multiple NTP Servers. |