UCF STIG Viewer Logo

The storage system must record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT).


Overview

Finding ID Version Rule ID IA Controls Severity
V-237831 HP3P-32-001701 SV-237831r647902_rule Low
Description
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. Time stamps generated by the operating system include date and time. Time is commonly expressed in UTC, a modern continuation of GMT, or local time with an offset from UTC.
STIG Date
HPE 3PAR StoreServ 3.2.x Security Technical Implementation Guide 2021-11-23

Details

Check Text ( C-41041r647900_chk )
Verify the "Timezone" field is configured by entering the following command:

cli% showdate
Node Date
0 2016-05-18 23:46:29 UTC (Etc/UTC)
1 2016-05-18 23:46:37 UTC (Etc/UTC)

If the output does not match the required time zone, this is a finding.
Fix Text (F-41000r647901_fix)
Configure the "Timezone" field by first identifying the time zone identifier.

Enter the command to list available time zone settings:

cli% setdate -tzlist

If UTC is to be set, then use the following command:

cli% setdate -tz Etc/UTC