The storage system must allocate audit record storage capacity to store at least one weeks worth of audit records, when audit records are not immediately sent to a central audit record storage facility.


Overview

Finding ID Version Rule ID IA Controls Severity
V-237830 HP3P-32-001700 SV-237830r647899_rule Medium
Description
To verify operating systems have a sufficient storage capacity in which to write the audit logs, operating systems need to be able to allocate audit record storage capacity. The task of allocating audit record storage capacity is usually performed during initial installation of the operating system.
STIG Date
HPE 3PAR StoreServ 3.2.x Security Technical Implementation Guide 2021-11-23

Details

Check Text ( C-41040r647897_chk )
Verify the logging capacity is set to the maximum value of "4", with the following command:

cli% showsys -param

If the resulting list of configured parameters and values, does not contain "EventLogSize : 4M", this is a finding.
Fix Text (F-40999r647898_fix)
Configure the audit logging capacity for the maximum storage value by entering the command:

cli% setsys EventLogSize 4M