UCF STIG Viewer Logo

The HP FlexFabric Switch must record time stamps for audit records that meet a granularity of one second for a minimum degree of precision.


Overview

Finding ID Version Rule ID IA Controls Severity
V-66255 HFFS-ND-000102 SV-80745r1_rule Medium
Description
Without sufficient granularity of time stamps, it is not possible to adequately determine the chronological order of records. Time stamps generated by the application include date and time. Granularity of time measurements refers to the degree of synchronization between information system clocks and reference clocks.
STIG Date
HP FlexFabric Switch NDM Security Technical Implementation Guide 2020-06-03

Details

Check Text ( C-66901r1_chk )
Check if info-center is configured to provide timestamp:

[HP] display info-center

Information Center: Enabled
Console: Enabled
Monitor: Enabled
Log host: Enabled
192.100.50.27,
port number: 514, host facility: local7
Log buffer: Enabled
Max buffer size 1024, current buffer size 512
Current messages 66, dropped messages 0, overwritten messages 0
Log file: Enabled
Security log file: Enabled
Information timestamp format:
Log host: Date
Other output destination: Date
Check logfile content to determine if the time stamp is present:

cd logfile/
more logfile.log
%@9377%Jan 20 23:31:03:567 2011 HP5930_SUT SHELL/6/SHELL_CMD: -Line=vty0-IPAddr=16.123.122.155-User=admin; Command is dis info-center
%@9378%Jan 20 23:31:09:342 2011 HP5930_SUT SHELL/6/SHELL_CMD: -Line=vty0-IPAddr=16.123.122.155-User=admin; Command is qui

If the HP FlexFabric Switch is not configured to enable timestamp, this is a finding.
Fix Text (F-72331r1_fix)
Configure timestamp on the logs on the HP FlexFabric Switch:

[HP] info-center timestamp date

By default, the device uses internal system clocks to generate time stamps for audit records in the date format - MMM DD hh:mm:ss:xxx YYYY which provides required granularity.