Take Survey

The HP FlexFabric Switch must synchronize internal information system clocks to the authoritative time source when the time difference is greater than the organization-defined time period.


Overview

Finding ID Version Rule ID IA Controls Severity
V-66249 HFFS-ND-000099 SV-80739r1_rule Medium
Description
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network. Organizations should consider setting time periods for different types of systems (e.g., financial, legal, or mission-critical systems). Organizations should also consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints). This requirement is related to the comparison done every 24 hours in CCI-001891 because a comparison must be done in order to determine the time difference. The organization-defined time period will depend on multiple factors, most notably the granularity of time stamps in audit logs. For example, if time stamps only show to the nearest second, there is no need to have accuracy of a tenth of a second in clocks.
STIG Date
HP FlexFabric Switch NDM Security Technical Implementation Guide 2020-06-03

Details

Check Text ( C-66895r1_chk )
Check the HP FlexFabric Switch configuration to determine if it synchronizes internal information system clocks to the authoritative time source when the time difference is greater than the organization-defined time period.

[HP] display ntp status

Clock status: synchronized
Clock stratum: 4
System peer: 16.110.135.123
Local mode: client
Reference clock ID: 16.110.135.123
Leap indicator: 00
Clock jitter: 0.004227 s
Stability: 0.000 pps
Clock precision: 2^-19
Root delay: 96.75598 ms
Root dispersion: 149.76501 ms
Reference time: d916fabd.a5c6d326 Mon, Jun 1 2015 9:37:33.647

If this synchronization is not occurring when the time difference is greater than the organization-defined time period, this is a finding.
Fix Text (F-72325r1_fix)
Configure the HP FlexFabric Switch to synchronize internal information system clocks to the authoritative time source when the time difference is greater than the organization-defined time period.

[HP] ntp enable
[HP] ntp unicast-server 16.110.135.123