UCF STIG Viewer Logo

The HP FlexFabric Switch must compare internal information system clocks at least every 24 hours with an authoritative time server.


Overview

Finding ID Version Rule ID IA Controls Severity
V-66247 HFFS-ND-000098 SV-80737r1_rule Medium
Description
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside of the configured acceptable allowance (drift) may be inaccurate. Additionally, unnecessary synchronization may have an adverse impact on system performance and may indicate malicious activity. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network.
STIG Date
HP FlexFabric Switch NDM Security Technical Implementation Guide 2020-06-03

Details

Check Text ( C-66893r1_chk )
Check the HP FlexFabric Switch configuration to determine if compares internal information system clocks at least every 24 hours with an authoritative time server.

[HP] display ntp status

Clock status: synchronized
Clock stratum: 4
System peer: 16.110.135.123
Local mode: client
Reference clock ID: 16.110.135.123
Leap indicator: 00
Clock jitter: 0.004227 s
Stability: 0.000 pps
Clock precision: 2^-19
Root delay: 96.75598 ms
Root dispersion: 149.76501 ms
Reference time: d916fabd.a5c6d326 Mon, Jun 1 2015 9:37:33.647

If this comparison does not occur at least every 24 hours, this is a finding.
Fix Text (F-72323r1_fix)
Configure the HP FlexFabric Switch to compare internal information system clocks at least every 24 hours with an authoritative time server.

[HP] ntp enable
[HP] ntp unicast-server 16.110.135.123