Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-66187 | HFFS-ND-000032 | SV-80677r1_rule | Low |
Description |
---|
Reconstruction of harmful events or forensic analysis is not possible if audit records do not contain enough information. Organizations consider limiting the additional audit information to only that information explicitly needed for specific audit requirements. The additional information required is dependent on the type of information (i.e., sensitivity of the data and the environment within which it resides). At a minimum, the organization must audit full-text recording of privileged commands. The organization must maintain audit trails in sufficient detail to reconstruct events to determine the cause and impact of compromise. |
STIG | Date |
---|---|
HP FlexFabric Switch NDM Security Technical Implementation Guide | 2020-06-03 |
Check Text ( C-66833r1_chk ) |
---|
Determine if the info-center feature is enabled on the HP FlexFabric Switch: [HP] display info-center Information Center: Enabled If logging is not enabled, this is a finding. |
Fix Text (F-72263r1_fix) |
---|
Enable info-center feature on the HP FlexFabric Switch: [HP] info-center enable Note: By default, the information center is enabled. |