The HP FlexFabric Switch must generate audit records containing the full-text recording of privileged commands.


Overview

Finding ID Version Rule ID IA Controls Severity
V-66187 HFFS-ND-000032 SV-80677r1_rule Low
Description
Reconstruction of harmful events or forensic analysis is not possible if audit records do not contain enough information. Organizations consider limiting the additional audit information to only that information explicitly needed for specific audit requirements. The additional information required is dependent on the type of information (i.e., sensitivity of the data and the environment within which it resides). At a minimum, the organization must audit full-text recording of privileged commands. The organization must maintain audit trails in sufficient detail to reconstruct events to determine the cause and impact of compromise.
STIG Date
HP FlexFabric Switch NDM Security Technical Implementation Guide 2020-06-03

Details

Check Text ( C-66833r1_chk )
Determine if the info-center feature is enabled on the HP FlexFabric Switch:

[HP] display info-center

Information Center: Enabled

If logging is not enabled, this is a finding.
Fix Text (F-72263r1_fix)
Enable info-center feature on the HP FlexFabric Switch:

[HP] info-center enable

Note: By default, the information center is enabled.