UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The HP FlexFabric Switch must protect against an individual (or process acting on behalf of an individual) falsely denying having performed organization-defined actions to be covered by non-repudiation.


Overview

Finding ID Version Rule ID IA Controls Severity
V-66165 HFFS-ND-000021 SV-80655r1_rule Low
Description
This requirement supports non-repudiation of actions taken by an administrator and is required in order to maintain the integrity of the configuration management process. All configuration changes to the HP FlexFabric Switch are logged, and administrators authenticate with two-factor authentication before gaining administrative access. Together, these processes will ensure the administrators can be held accountable for the configuration changes they implement. To meet this requirement, the HP FlexFabric Switch must log administrator access and activity.
STIG Date
HP FlexFabric Switch NDM Security Technical Implementation Guide 2020-06-03

Details

Check Text ( C-66811r1_chk )
Check the HP FlexFabric log file to determine if logging is enabled:

[HP] display info-center

Information Center: Enabled

If the HP FlexFabric Switch does not have logging enabled, this is a finding.
Fix Text (F-72241r1_fix)
Enable informational center on the HP FlexFabric Switch:

[HP] info-center enable