The HP FlexFabric Switch must generate an immediate real-time alert of all audit failure events requiring real-time alerts.


Overview

Finding ID Version Rule ID IA Controls Severity
V-66245 HFFS-ND-000097 SV-80735r1_rule Medium
Description
It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected. Alerts provide organizations with urgent messages. Real-time alerts provide these messages immediately (i.e., the time from event detection to alert occurs in seconds or less).
STIG Date
HP FlexFabric Switch NDM Security Technical Implementation Guide 2019-09-27

Details

Check Text ( C-66891r1_chk )
Determine if the HP FlexFabric Switch provides the capability for organization-identified individuals or roles to change the auditing to be performed based on all selectable event criteria within near-real-time.

[HP] display info-center

Information Center: Enabled
Console: Enabled
Monitor: Enabled
Log host: Enabled
192.100.50.27,
port number: 514, host facility: local7
Log buffer: Enabled
Max buffer size 1024, current buffer size 512
Current messages 66, dropped messages 0, overwritten messages 0
Log file: Enabled
Security log file: Enabled
Information timestamp format:
Log host: Date
Other output destination: Date

If the HP FlexFabric Switch does not provide the capability for organization-identified individuals or roles to change the auditing to be performed based on all selectable event criteria within near-real-time, this is a finding.
Fix Text (F-72321r1_fix)
Configure the HP FlexFabric Switch to generate an immediate real-time alert of all audit failure events requiring real-time alerts.

[HP] info-center enable