Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-66173 | HFFS-ND-000025 | SV-80663r1_rule | Low |
Description |
---|
If auditing is enabled late in the startup process, the actions of some start-up processes may not be audited. Some audit systems also maintain state information only available if auditing is enabled before a given process is created. |
STIG | Date |
---|---|
HP FlexFabric Switch NDM Security Technical Implementation Guide | 2019-09-27 |
Check Text ( C-66819r1_chk ) |
---|
Determine if the info-center feature is enabled on the HP FlexFabric Switch: [HP] display info-center Information Center: Enabled If logging is not enabled, this is a finding. |
Fix Text (F-72249r1_fix) |
---|
Enable info-center feature on the HP FlexFabric Switch: [HP] info-center enable Note: By default, the information center is enabled. |