UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The HP FlexFabric Switch must have all disabled switch ports assigned an unused VLAN.


Overview

Finding ID Version Rule ID IA Controls Severity
V-66085 HFFS-L2-000024 SV-80575r1_rule Medium
Description
It is possible that a disabled port that is assigned to a user or management VLAN becomes enabled by accident or by an attacker and as a result gains access to that VLAN as a member.
STIG Date
HP FlexFabric Switch L2S Security Technical Implementation Guide 2020-06-03

Details

Check Text ( C-66729r1_chk )
Review the HP FlexFabric Switch configurations and examine all access switch ports. Each access switch port not in use should have membership to an inactive VLAN that is not used for any purpose and is not allowed on any trunk links.

If there are any access switch ports not in use and not in an inactive VLAN, this is a finding.

display vlan X
VLAN ID: X
VLAN type: Static
Route interface: Configured:
Description: VLAN 000X
Name: VLAN 000X
Tagged ports: None
Untagged ports:
GigabitEthernet1/0/1 GigabitEthernet1/0/2
GigabitEthernet1/0/3 GigabitEthernet1/0/4
Fix Text (F-72161r1_fix)
Assign all switch ports not in use to an inactive VLAN.

[HP-vlanX]port GigabitEthernet 1/0/1 to GigabitEthernet 1/0/48