Google Android 14 must be configured to disallow configuration of date and time.


Overview

Finding ID Version Rule ID IA Controls Severity
V-258437 GOOG-14-010600 SV-258437r959010_rule Medium
Description
Determining the correct time a particular application event occurred on a system is critical when conducting forensic analysis and investigating system events. Periodically synchronizing internal clocks with an authoritative time source is necessary to correctly correlate the timing of events that occur across the enterprise. The three authoritative time sources for Google Android 14 are an authoritative time server that is synchronized with redundant United States Naval Observatory (USNO) time servers as designated for the appropriate DOD network (NIPRNet or SIPRNet), or the Global Positioning System (GPS), or the wireless carrier. Time stamps generated by the audit system in Google Android 14 must include both date and time. The time may be expressed in Coordinated Universal Time (UTC), a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC. SFR ID: FMT_SMF_EXT.1.1 #47
STIG Date
Google Android 14 COPE Security Technical Implementation Guide 2024-06-05

Details

Check Text ( C-62178r928334_chk )
Review the managed Google Android 14 device configuration settings to confirm that autofill services are disabled.

This procedure is performed on both the EMM Administration console and the managed Google Android 14 device.

On the EMM console:

COBO:

1. Open "Set user restrictions".
2. Verify "Disallow config date time" is toggled to "ON".

COPE:

1. Open "Set user restrictions on parent".
2. Verify "Disallow config date time" is toggled to "ON".

On the managed Google Android 14 device:

COBO and COPE:

1. Open Settings.
2. Tap "System".
3. Tap "Date & time".
4. Verify "Set time automatically" is grayed out and is "Enabled by admin".

If on the EMM console "Disallow config date time" is not set to "On", or on the managed Android 14 device "Set time automatically" is not grayed out, this is a finding.
Fix Text (F-62102r928335_fix)
Configure the Google Android 14 device to set auto network time.

On the EMM console:

COBO:

1. Open "Set user restrictions".
2. Toggle "Disallow config date time" to "ON".

COPE:

1. Open "Set user restrictions on parent".
2. Toggle "Disallow config date time" to "ON".