UCF STIG Viewer Logo

Google Android 11 must be configured to disallow configuration of date and time.


Overview

Finding ID Version Rule ID IA Controls Severity
V-228601 GOOG-11-010200 SV-228601r510289_rule Medium
Description
Determining the correct time a particular application event occurred on a system is critical when conducting forensic analysis and investigating system events. Periodically synchronizing internal clocks with an authoritative time source is necessary to correctly correlate the timing of events that occur across the enterprise. The three authoritative time sources for Google Android 11 are an authoritative time server that is synchronized with redundant United States Naval Observatory (USNO) time servers as designated for the appropriate DoD network (NIPRNet or SIPRNet), or the Global Positioning System (GPS), or the wireless carrier. Time stamps generated by the audit system in Google Android 11 must include both date and time. The time may be expressed in Coordinated Universal Time (UTC), a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC. SFR ID: FMT_SMF_EXT.1.1 #47
STIG Date
Google Android 11 COBO Security Technical Implementation Guide 2020-09-18

Details

Check Text ( C-30836r505628_chk )
Review the Google Android 11 Work Profile configuration settings to confirm that autofill services are disabled.

This procedure is performed on both the EMM Administration console and the Google Android 11 device.

On the EMM console:
1. Open "Set user restrictions on parent".
2. Verify that "Disallow config date time" is toggled to On.

On the Google Android 11 device, do the following:
1. Open Settings.
2. Tap "System".
3. Tap "Date & times".
4. Validate that "Use network-provided time" is grayed out.

If on the EMM console "Disallow config date time" is not set to On, or on the Google Android 11 device "User network-provided time" is not grayed out, this is a finding.
Fix Text (F-30813r505629_fix)
Configure Google Android 11 work Profile to set auto network time.

On the EMM console:
1. Open "Set user restrictions on parent".
2. Toggle "Disallow config date time" to On.