Forescout must generate log records when concurrent logons from different workstations occur.


Overview

Finding ID Version Rule ID IA Controls Severity
V-230942 FORE-NM-000140 SV-230942r961833_rule Low
Description
Without generating log records that are specific to the security and mission needs of the organization, it would be difficult to establish, correlate, and investigate the events relating to an incident or identify those responsible for one. Log records can be generated from various components within the network device (e.g., module or policy filter).
STIG Date
Forescout Network Device Management Security Technical Implementation Guide 2024-06-10

Details

Check Text ( C-33872r603665_chk )
Verify the syslog trigger is configured.

1. Log on to Forescout Administrator UI with admin or operator credentials.
2. From the menu, select Tools >> Options >> Modules >> Syslog >> Syslog Triggers.
3. Under User Operations, verify "Include user operations" is checked.

If Forescout does not generate log records when concurrent logons from different workstations occur, this is a finding.
Fix Text (F-33845r603666_fix)
Configure the syslog trigger.

1. Log on to Forescout Administrator UI with admin or operator credentials.
2. From the menu, select Tools >> Options >> Modules >> Syslog >> Syslog Triggers.