UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

Forescout must be configured to use Coordinated Universal Time (UTC).


Overview

Finding ID Version Rule ID IA Controls Severity
V-230945 FORE-NM-000170 SV-230945r615886_rule Medium
Description
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. Time stamps generated by the application include date and time. Time is commonly expressed in Coordinated Universal Time (UTC), a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC.
STIG Date
Forescout Network Device Management Security Technical Implementation Guide 2020-12-11

Details

Check Text ( C-33875r603674_chk )
Determine if Forescout records time stamps for log records that can be mapped to UTC. This requirement may be verified by demonstration or configuration review.

Verify by connecting to the appliance via SSH using standard user/operator privilege.

1. Type "date" at the command prompt.
2. Verify the date references accurate time and "UTC" shows just before the year.

If Forescout does not record time stamps for log records that can be mapped to UTC, this is a finding.
Fix Text (F-33848r603675_fix)
Configure Forescout to record time stamps for log records that can be mapped to UTC.

Note: Updating time preferences will force Forescout into maintenance mode and the service must be restarted. Use a scheduled outage for planned maintenance and stop Forescout service prior to adjusting time settings.

1. Type the following command at the prompt using the IP address of the required NTP server:
fstool ntp
2. Ensure the date references accurate time and the time zone points to UTC next to the year.