Forescout must perform continuous detection and tracking of endpoint devices attached to the network. This is required for compliance with C2C Step 1.


Overview

Finding ID Version Rule ID IA Controls Severity
V-233337 FORE-NC-000440 SV-233337r811425_rule Medium
Description
Continuous scanning capabilities on the NAC provide visibility of devices that are connected to the switch ports. The NAC continuously scans networks and monitors the activity of managed and unmanaged devices, which can be personally owned or rogue endpoints. Because many of today's small devices do not include agents, an agentless discovery is often combined to cover more types of equipment.
STIG Date
Forescout Network Access Control Security Technical Implementation Guide 2021-12-17

Details

Check Text ( C-36532r811424_chk )
If DoD is not at C2C Step 1 or higher, this is not a finding.

Verify the NAC performs continuous detection and tracking of endpoint devices attached to the network.

1. Log on to the Forescout UI.
2. Go to Tools >> Options >> Appliance >> IP Assignment.
3. Check that all IP addresses that should be managed are within the IP Assignments as required by the SSP.

If the NAC does not perform continuous detection and tracking of endpoint devices attached to the network, this is a finding.
Fix Text (F-36497r605715_fix)
Log on to the Forescout UI.

1. Go to Tools >> Options >> Appliance >> IP Assignment.
2. Enter all IP addresses to be managed in the IP Assignment to enable the continuous monitoring capabilities of Forescout.