Forescout must be configured to log records onto a centralized events server.


Overview

Finding ID Version Rule ID IA Controls Severity
V-233323 FORE-NC-000150 SV-233323r611394_rule Medium
Description
Keeping an established, connection-oriented audit record is essential to keeping audit logs in accordance with DoD requirements.
STIG Date
Forescout Network Access Control Security Technical Implementation Guide 2020-12-11

Details

Check Text ( C-36518r605672_chk )
1. Go to Tools >> Options >> Syslog.
2. Verify a central log server's IP address is configured.

If Forescout does not configured to log records onto a centralized events server, this is a finding.
Fix Text (F-36483r605673_fix)
Configure Syslog server with TCP, as well as configure Syslog to alert if the communication between the Syslog server and the Forescout appliance loses connectivity.

1. Go to Tools >> Options >> Syslog.
2. Click Add/Edit.
3. Configure the Syslog:
- Syslog Server IP address
- Server Port
- Server Protocol set to TCP
- Check the Use TLS setting
- Configure the Identity, Facility, and Severity.
4. Click "Ok".
5. Click "Apply".

Note: A secondary syslog server is required to fully meet this requirement (covered in NDM STIG). Use the same instructions to configure a second syslog.