UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The firewall must generate an alert that can be forwarded to, at a minimum, the ISSO and ISSM when denial-of-service (DoS) incidents are detected.


Overview

Finding ID Version Rule ID IA Controls Severity
V-79489 SRG-NET-000392-FW-000042 SV-94195r1_rule Low
Description
Without an alert, security personnel may be unaware of major detection incidents that require immediate action, and this delay may result in the loss or compromise of information. The firewall generates an alert that notifies designated personnel of the Indicators of Compromise (IOCs), which require real-time alerts. These messages should include a severity level indicator or code as an indicator of the criticality of the incident. These indicators reflect the occurrence of a compromise or a potential compromise. Since these incidents require immediate action, these messages are assigned a critical or level 1 priority/severity, depending on the system's priority schema. CJCSM 6510.01B, "Cyber Incident Handling Program", lists nine Cyber Incident and Reportable Event Categories. DoD has determined that categories identified by CJCSM 6510.01B Major Indicators (category 1, 2, 4, or 7 detection events) will require an alert when an event is detected. Alerts may be transmitted, for example, telephonically, by electronic mail messages, or by text messaging. The firewall must either send the alert to a management console that is actively monitored by authorized personnel or use a messaging capability to send the alert directly to designated personnel.
STIG Date
Firewall Security Requirements Guide 2019-06-28

Details

Check Text ( C-79117r1_chk )
If a network device such as the events, network management, or SNMP server is configured to send an alert when DoS incidents are detected, this is not a finding.

Verify the firewall is configured to send an alert via instant message, email, SNMP, or another authorized method to the ISSO, ISSM, and other identified personnel when DoS incidents are detected.

If the firewall is not configured to send an alert via an approved and immediate method when DoS incidents are detected, this is a finding.
Fix Text (F-86263r1_fix)
Configure the firewall (or another network device) to send an alert via instant message, email, or another authorized method to the ISSO and ISSM and other identified personnel when DoS incidents are detected.