UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The BIG-IP appliance must limit the number of concurrent sessions to the Configuration Utility to 10 or an organization-defined number.


Overview

Finding ID Version Rule ID IA Controls Severity
V-217381 F5BI-DM-000003 SV-217381r557520_rule Medium
Description
Device management includes the ability to control the number of administrators and management sessions that manage a device. Limiting the number of allowed administrators and sessions per administrator is helpful in limiting risks related to DoS attacks. This requirement addresses concurrent sessions for administrative accounts and does not address concurrent sessions by a single administrator via multiple administrative accounts. The maximum number of concurrent sessions should be defined based upon mission needs and the operational environment for each system.
STIG Date
F5 BIG-IP Device Management 11.x Security Technical Implementation Guide 2020-09-28

Details

Check Text ( C-18606r290697_chk )
Verify the BIG-IP appliance is configured to limit the number of concurrent sessions to 10 or an organization-defined number.

Navigate to the BIG-IP System manager >> System >> Preferences.

Set "System Settings:" to "Advanced".

Verify "Maximum HTTP Connections to Configuration Utility" is set to the organization-defined number of concurrent sessions.

If neither of these configurations is present, this is a finding.
Fix Text (F-18604r290698_fix)
Configure the BIG-IP appliance either to limit the number of concurrent sessions to 10 or an organization-defined number.