Finding ID | Version | Rule ID | IA Controls | Severity |
---|---|---|---|---|
V-60255 | F5BI-DM-000135 | SV-74685r1_rule | Medium |
Description |
---|
Unapproved mechanisms that are used for authentication to the cryptographic module are not verified and therefore cannot be relied upon to provide confidentiality or integrity, and DoD data may be compromised. Network devices utilizing encryption are required to use FIPS-compliant mechanisms for authenticating to cryptographic modules. FIPS 140-2 is the current standard for validating that mechanisms used to access cryptographic modules utilize authentication that meets DoD requirements. |
STIG | Date |
---|---|
F5 BIG-IP Device Management 11.x Security Technical Implementation Guide | 2019-12-20 |
Check Text ( C-61177r1_chk ) |
---|
Verify the BIG-IP appliance is configured to use a properly configured authentication server that uses mechanisms meeting the requirements of applicable federal laws, Executive Orders, directives, policies, regulations, standards, and guidance for authentication to a cryptographic module. Navigate to the BIG-IP System manager >> System >> Users >> Authentication. Verify "Authentication: User Directory" is configured for an approved remote authentication server that uses mechanisms meeting the requirements of applicable federal laws, Executive Orders, directives, policies, regulations, standards, and guidance for authentication to a cryptographic module. If the BIG-IP appliance is not configured to use a properly configured authentication server that uses mechanisms that meet the requirements for authentication to a cryptographic module, this is a finding. |
Fix Text (F-65869r1_fix) |
---|
Configure the BIG-IP appliance to use a properly configured authentication server that uses mechanisms meeting the requirements of applicable federal laws, Executive Orders, directives, policies, regulations, standards, and guidance for authentication to a cryptographic module. |