UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The BIG-IP appliance must be configured to shut down by default upon audit failure (or restart when availability is an overriding concern).


Overview

Finding ID Version Rule ID IA Controls Severity
V-60125 F5BI-DM-000069 SV-74555r1_rule Low
Description
It is critical that when the network device is at risk of failing to process audit logs as required, it take action to mitigate the failure. Audit processing failures include: software/hardware errors; failures in the audit capturing mechanisms; and audit storage capacity being reached or exceeded. Responses to audit failure depend upon the nature of the failure mode. When availability is an overriding concern, other approved actions in response to an audit failure are as follows: 1) If the failure was caused by the lack of audit record storage capacity, the network device must continue generating audit records if possible (automatically restarting the audit service if necessary), overwriting the oldest audit records in a first-in-first-out manner; or 2) If audit records are sent to a centralized collection server and communication with this server is lost or the server fails, the network device must queue audit records locally until communication is restored or until the audit records are retrieved manually. Upon restoration of the connection to the centralized collection server, action should be taken to synchronize the local audit data with the collection server.
STIG Date
F5 BIG-IP Device Management 11.x Security Technical Implementation Guide 2019-12-20

Details

Check Text ( C-60945r1_chk )
Verify the BIG-IP appliance is configured to shut down or restart upon audit failure.

Navigate to the BIG-IP System manager >> System >> High Availability >> Fail-Safe >> System.

Verify "Switch Board Failure" under the "System Trigger Properties" section is set to perform the appropriate action based on the location of the device.

If the BIG-IP appliance is not configured to shut down or restart upon audit failure, this is a finding.
Fix Text (F-65677r1_fix)
Configure the BIG-IP appliance to shut down or restart upon audit failure, based on the location of the device.