UCF STIG Viewer Logo
Changes are coming to https://stigviewer.com. Take our survey to help us understand your usage and how we can better serve you in the future.
Take Survey

The BIG-IP appliance must be configured to alert the ISSO and SA (at a minimum) in the event of an audit processing failure.


Overview

Finding ID Version Rule ID IA Controls Severity
V-60123 F5BI-DM-000067 SV-74553r1_rule Low
Description
It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without this notification, the security personnel may be unaware of an impending failure of the audit capability, and system operation may be adversely affected. Audit processing failures include software/hardware errors, failures in the audit capturing mechanisms, and audit storage capacity being reached or exceeded.
STIG Date
F5 BIG-IP Device Management 11.x Security Technical Implementation Guide 2019-12-20

Details

Check Text ( C-60943r1_chk )
Verify the BIG-IP appliance is configured to alert the ISSO and SA (at a minimum) in the event of an audit processing failure.

Navigate to the BIG-IP System manager >> System >> Logs >> Configuration >> Options.

Verify "MCP" under the "Audit Logging" section is set to Debug.

If the BIG-IP appliance is not configured to alert in the event of an audit processing failure, this is a finding.
Fix Text (F-65675r1_fix)
Configure the BIG-IP appliance to alert the ISSO and SA (at a minimum) in the event of an audit processing failure.